The Common Equipment Facility located in Rms. 401-2 and 401-7 houses many basic instruments, including T-Gradient and Real-time Quantitative PCR machines, microplate reader and NanoDrop, spectrophotometers, gel/membrane imaging systems, High-Performance and Ultra-Performance Liquid Chromatography, flow cytometers (analyzers), an automated microfluidic capillary electrophoresis system, an XcelVap evaporation/concentration system, Seahorse Analyzer, Disruptor and homogenizer.
|
|
| |
| |
Common Equipment Rms. 401-2 and 401-7
|
| |
Contact: Shin-Yi Du Tel-9527 |
<Flow cytometry>
|
|
Items
|
Equipment
|
Brand/Model
|
Applications
|
Link
|
|
1
|
Flow analyzer
|
BD, FACSCantoII
|
A benchtop cell analyzer, equipped with 2 lasers.
- Laser excitation wavelength: 488, 633nm.
- Fluorescence detectors: 6 PMTs.
- Flow rate: 10, 60, 120ul/min.
- Sample capability: 5mL BD Falcon Polystyrene round-bottom tube.
- Autosampler: 40-tube carousel.
|
Quick guide
Spec. sheet
On-line reservation system
|
|
2
|
Flow analyzer
|
Thermo Fisher Scientific ,
Attune™ NxT |
A benchtop cell analyzer, equipped with 4 lasers and acoustic-assisted hydrodynamic focusing apparatus.
- Laser excitation wavelength: 405, 488, 561, 637nm
- Fluorescence detectors: 14 PMTs.
- Flow rate: 12.5, 25, 100, 200, 500, 1000ul/min.
- Sample capability: 1.5-2mL eppendorf, micro tube, 5mL tube (ex. BD Falcon Polystyrene round-bottom tube)
|
Quick guide
Spec. sheet
Fluorophore Selection Guilde
On-line reservation system
|
|
| |
<PCR machine>
|
|
Items
|
Equipment
|
Brand/Model
|
Applications
|
Link
|
| 1 |
TGradient PCR
|
Biometra,
TGradient96 Thermocycler |
- Through a temperature gradient setting, it allows the detection of the perfect annealing temperature in a single PCR run.
- Temp. gradient: 40 °C.
- Temp. range: -3 – 99.9°C.
- Sample capacity: 0.2ml PCR tubes (max. 96), 96-well microplates or strips.
|
Biometra_TGradient_user manual
|
| 2 |
Real-time PCR
|
Roche, LightCycler480
I ,II & III |
- Perform gene quantification (relative or absolute), genetic variations analysis or other applications in need of detecting FL intensity in each PCR cycle.
- Excitation source: Xenon lamp (430-630nm).
- Excitation filters: 440, 465, 498, 533, 618nm.
- Emission filters: 488, 510, 580, 610, 640, 660nm.
- Detection: CCD camera.
- Max. heating rate: 4.4 °C/sec.
- Max. cooling rate: 2.2 °C/sec.
- Sample capacity: 96- or 384-well PCR plate.
|
LightCycler480 II_Manual_V1.5
HRM_strategy
On-line reservation
|
|
| |
<Spectrophotometers>
|
|
Items
|
Equipment
|
Brand/Model
|
Applications
|
Link
|
| 1
|
Nanodrop 1000 |
PerkinElmer
ND-1000 Spectrophotometer
|
- Quantify DNA, RNA and protein samples in seconds with 1-2µL.
- Light source: Xenon lamp (220-750nm).
- Sample Vol. range: 1-2µL.
- Sample no. per measurement: one.
- Detection dynamic range: 2-3700 ng/µL for dsDNA.
- Abs. range: 0.02-75 Abs.
|
Notice before usage'
ND 1000 Manual v3.7
|
| 2 |
Nanodrop 2000C |
Thermo Scientific, Nanodrop 2000C Spectrophotometer |
- Quantify DNA, RNA and protein samples in seconds with 1-2µL.
- Light source: Xenon lamp (190-840nm).
- Sample Vol. range: 1-2µL.
- Sample no. per measurement: one.
- Detection dynamic range: Pedestal: 2-15,000 ng/µL for dsDNA, Cuvette: 0.4-750 ng/µL for dsDNA.
- Abs. range: Pedestal: 0-300 Abs, Cuvette: 0-1.5 Abs.
|
ND 2000c Manual |
| 3 |
Nanodrop 8000 |
Thermo Scientific, Nanodrop 8000 Spectrophotometer |
- Quantify DNA, RNA and protein samples in seconds with 1-2µL.
- Light source: Xenon lamp (220-750nm).
- Sample Vol. range: 1-2µL.
- Sample no. per measurement: up to eight.
- Detection dynamic range: 2.5-3700 ng/µL for dsDNA.
- Abs. range: 0–75 Abs.
|
ND 8000 Manual
|
| 4 |
Microplate reader |
BioRad, Model 680 |
- Detection mode: Absorbance (Abs).
- Sample capacity: 96-well microplate.
- Light source: Tungsten halogen lamp.
- Detector: Silicon hotodiodes.
- Wavelength selection by filters: 415, 450, 490, 595, 655nm.
|
Model 680_quick guide in Chinese
|
| 5 |
Microplate reader
(multi-detection)
|
Molecular Devices, SpectraMax M5 |
- Detection mode: UV-Visible Absorbance (Abs), Fluorescence Intensity (FI), Luminescence (Lum), Time-Resolved Fluorescence (TRF), Fluorescence Polarization (FP).
- Sample capacity: 6-384 well microplate or cuvette.
- Light source: Xenon lamp.
- Detector: PMTs.
- Wavelength selection by monochromators.
- Abs. wavelength: 200-1000nm.
- FI wavelength: 250-850nm.
- Lum wavelength: 250-850nm.
- FP wavelength: 300-750nm.
|
M5 manual in Chinese
M5 software User guide
M5 specification
|
| 6 |
EnSpire |
PerkinElmer |
- Detection mode: UV-Visible Absorbance (Abs), Fluorescence Intensity (FI), Luminescence (Lum), Time-Resolved Fluorescence (TRF), AlphaScreen.
- Sample capacity: 6-384 well microplate.
- Light source: Xenon lamp.
- Detector: PMTs.
- Wavelength selection by monochromators.
- Abs. wavelength: 230-1000nm.
- FI wavelength: 230-850nm.
- Lum wavelength: 250-850nm.
- Injector no./Vol. range: 2 / 1 - 475 μl per stroke.
|
Dispenser quick guide
EnSpire_quick guide in Chinese
EnSpire(2300)_manual
|
| 7 |
Microplate reader (multi-mode) |
SpectraMax iD5 / Molecular Devices |
1. Detection mode: UV-Visible Absorbance (Abs), Fluorescence Intensity (FI), Luminescence (Lum), enhanced Time-Resolved Fluorescence (TRF), Fluorescence Polarization (FP).
2. Sample capacity: 6-384 well microplate or cuvette.
3. Light source: Xenon lamp.
4. Detector: PMTs.
5. Wavelength selection by monochromators.
6. Abs. wavelength: 230-1000nm.
7. FI wavelength: 250-850nm.
8. Lum wavelength: 300-850nm.
9. FP wavelength: 400-750nm. |
User manual in Chinese |
|
| |
<Liquid Chromatography>
|
|
Items
|
Equipment
|
Brand/Model
|
Applications
|
Link
|
| 1 |
600E HPLC
|
Waters
600E HPLC |
The quaternary based 600E HPLC model equipped with an autosampler, a 2489 UV/VIS detector, a fluorescent detector and powerful Empower 2 software is applied for precise and reliable separations and analyses of biomolecules.
|
600e users guide |
| 2 |
ACQUITY UPLC H_Class
|
Waters ACQUITY UPLC H_Class
|
The sophisticated ACQUITY UPLC H-Class System, in combination with sub-2-μm packing technology, provides the highest resolution of any quaternary LC System. It also improves the characterization of most complex samples through enhanced resolution. For example, more than 20 AccQTag derivatized amino acids can be fully identified with 1 microliter volume injection at 10 pmol range detection within 10-min run.
Features:
- Flexibility of multi-solvent blending with the Quaternary Solvent Manager (QSM)
- High-precision injections with direct inject sampling
- Accurate temperature control across the entire column
- Low-dispersion detection capabilities
- Gradient SmartStart
- Supported in Empower 3
|
Link
User Guide
|
|
| |
<Gel/membrane imaging systems>
|
|
Items
|
Equipment
|
Brand/Model
|
Applications
|
Link
|
|
1
|
Geneflash (for EtBr stain)
|
Syngene, Geneflash
|
- For (documenting or digitalizing or detection) EtBr stain gel samples
- Excitation: 302nm
- Emission Filter: 605±25nm
|
|
|
2
|
BioDoc-It Imaging System (for non-EtBr stain)
|
UVP, BioDoc-It Imaging System
|
- For (documenting or digitalizing or detection) non-EtBr stain gel samples
- Excitation: 302, 365nm
- Emission Filter: 535±25, 605±25nm
|
Quick guide
|
|
3
|
BioSpectrum 600 Imaging System
|
UVP, BioSpectrum 600
|
- For (documenting or digitalizing or detection) gel or membrane of chemiluminescence, fluorescence and colorimetric.
- CCD camera/lens: monochrome, 16-bit, 3.2Mpixels/F1.2, 50mm.
- Light source: Epi- 365, 488nm, white; Transilluminator- 302nm, white.
- Emission Filter: Set 1- 485-655, 515-570, 570-640nm; Set 2- 513-557, 565-625, 607-682nm.
|
Operation guide
|
|
4
|
ImageQuant LAS4000 biomolecular imager
|
GE, ImageQuant LAS4000
|
- For (documenting or digitalizing or detection) gel or membrane of chemiluminescence, fluorescence and colorimetric.
- CCD camera/lens: monochrome, 16-bit, 3.2Mpixels/F0.85 43mm.
- Light source: LED Epi-blue, green, red, white; Transilluminator-302nm.
- Emission Filter: Y515, 575DF20, R670, 605DF40nm.
|
User Manual
Brochure with specification
|
|
<Seahorse XFe24 Analyzer>
|
|
|
| |
<Miscellaneous>
|
|
Items
|
Equipment
|
Brand/Model
|
Applications
|
Link
|
| 1 |
2100 Bioanalyzer
|
Agilent 2100 Bioanalyzer |
The Agilent Bioanalyzer utilizes microfluidics chips for determining RNA, DNA and protein quality, assessing labeled RNA or fragmented RNA size distributions, and genotyping by PCR. We currently only provide RNA QC services.
|
User Manual
|
|
2
|
Vacufuge Concentrator System |
eppendorf, Concentrator 5301 |
The concentrator dries and concentrates samples via centrifugal evaporation. |
User manual
|
| 3 |
LabChip GX
|
PerkinElmer |
The LabChip GX utilizes advanced microfluidics technology to perform reproducible, high-resolution, eletrophoretic separations for RNA and DNA samples.
|
on-line reservation system
User Manual |
|
4
|
XcelVap |
Horizon |
The XcelVap® is an automated evaporation and concentration System.
Features:
- Automated pressure profiling for optimum speed with no splattering or cross contamination.
- Nozzles can be individually changed or reconfigured for different racks by the user.
- Nitrogen blow-down evaporation of up to 54 sample extracts, ranging in size from less than 1 mL up to 200 mL
|
User Manual
|
| 6 |
Disruptor and homogenizer |
FastPrep-24 5G with CAM Lock / MP Biomedicals |
FastPrep-24 5G is a versatile sample disruptor designed to quickly and efficiently homogenize, grind, or lyse biological samples by shaking the samples in a tridimensional motion.
1. Shaking speed: 4 m/s - 10 m/s.
2. Shaking mode: tridimensional.
3. Time of per cycle: 1 - 120 s.
4. Cycle no.: 1 - 9 cycles.
5. Sample holder: 24x 2ml QuickPrep Adapter, 24x 2ml CoolPrep Adapter.
|
Quick guide in Chinese
Instruction manual in English
Suggested parameter settings
|
|
| |
Common Equipment Rules
|
Contact:Shin-Yi Du Tel-9527 |
| |
|
- If users are more than 15 minutes late for their appointment, the registration will be deemed cancelled.
- If any instrument failure or abnormality is detected, please stop immediately and notify the manager (Rm401-5). DO NOT CHANGE ANY SETTINGS OR RECONFIGURE ANY PART OF THE INSTRUMENTS.
- ALL activity on the instruments MUST be logged.
- Be sure that all equipment and work areas are carefully cleaned; EVERYTHING you may have brought into the lab, such as gloves, tubes, tips, samples, papers and bottles should be cleared away.
|
|